Technical solutions
Reagent programs, water treatment line and laboratory control from technologists who know the process.
Reagent programs by system
| System | Main problem | Reagent types |
|---|---|---|
| Recirculating cooling systems | Scale, corrosion, biological growth | Antiscalant, dispersant, corrosion inhibitor, biocides |
| Boilers and steam systems | Dissolved oxygen, CO₂ corrosion, hardness | Oxygen scavenger, neutralizing and filming amines, phosphate reagents |
| RO / UF / DM units | Membrane scaling, biofouling, organic fouling | Membrane antiscalant, biocide, acid and alkaline CIP cleaners |
| Water pre-treatment | Turbidity, iron, organics | Coagulant, flocculant, sodium hypochlorite, pH adjusters |
| Oil, gas and separation processes | Emulsions, H₂S, corrosion | Demulsifier, corrosion inhibitor, H₂S scavenger |
Water treatment line and chemical dosing points
Which reagents can be used at each stage:
Raw water
Full water analysis
DosingSampling and analysisPre-treatment
Coagulation, filtration
DosingCoagulant, flocculant, NaOCl, pH adjusterUltrafiltration (UF)
Suspended solids removal
DosingUF cleaning: NaOH, NaOCl, citric acidPre-RO conditioning
Cartridge filter, dosing
DosingNaHSO₃ (dechlorination), antiscalantReverse osmosis (RO)
Desalination
DosingAcid and alkaline CIPPolishing
EDI or mixed bed
DosingRegeneration: HCl, NaOH
Control parametersSDIORPConductivityDifferential pressureNormalized flow
From technical specification to reagent program
What we need from the client
- Water analysis results
- System type, volume and operating regime
- Operating temperature, pressure, cycles of concentration
- Equipment materials (steel, copper, stainless steel)
- Current reagent and its consumption
- Observed problems
The reagent program we prepare
- System description and problem analysis
- Selected reagents and their justification
- Dosing regime and calculation
- Control parameters and permissible limits
- Safety (SDS) and storage conditions
- Result criteria and monitoring schedule
Laboratory: analysis methods and equipment
| Parameter | Method and equipment |
|---|---|
| pH | Potentiometry, pH meter |
| Conductivity | Conductivity meter |
| Total hardness, Ca²⁺, Mg²⁺ | Complexometric titration (EDTA) |
| Alkalinity | Acid titration |
| Chlorides | Argentometric titration |
| Iron, silica, phosphate | Photometry, spectrophotometer |
| Turbidity | Turbidimeter |
How we choose an affordable, quality source
After receiving the technical specification we collect comparative offers from local and international manufacturers. The choice is not based on price alone: total delivered cost and quality are both taken into account.
- Technical specification
- Local and international sources
- Comparative offer
- Quality control
- Delivery
Price
total delivered cost
Quality
specification and certificate of analysis (COA)
Documents
certificate, SDS, country of origin
Lead time
availability and delivery time
Warranty
shelf life, contract terms
Have a technical specification or an inquiry?